The model run results cover the period December 20, through January 9, and are based on the following assumptions: Common Assumptions 1. CCFB Gates are operating to Priority 3 throughout the forecast period. 2. The Delta Cross Channel gates are closed throughout the forecast period. 3. Suisun Marsh salinity control flashboards are in and the three Suisun Marsh Salinity Control Gates are in open position throughout the forecast period. 4. San Joaquin River flow at Vernalis is at 1,456 cfs at the beginning of the forecast period and decreases to 1,000 cfs by the end forecast period. 5. San Joaquin River EC at Vernalis increases from 410 umhos/cm at the beginning of the forecast period to 590 umhos/cm by the end of forecast period. 6. CCFB is at 3,496 cfs at the beginning of the forecast period and will decrease to 2,800 cfs by the end of the forecast period. 7. Export at Jones Pumping Plant is at 3,527 cfs at the beginning of the forecast period and decreases to 2,800 cfs by the end of the forecast period.